The following are common faults and solutions during the operation of reverse osmosis water treatment equipment:
reason :
,
Insufficient pressure from the high-pressure pump, or excessively low water temperature.
Solution : Replace the filter element, chemically clean the RO membrane, overhaul the pump body, and raise the water temperature to around 25℃.
Solution : Replace the filter element, vent/maintain the pump, clean the valves, and replace the membrane module.
reason :
1. Seal leakage, abnormal concentrated water backflow, and deterioration of influent water quality.
Solution : Replace the membrane, replace the sealing ring, unclog the pipeline, and strengthen the pretreatment.
Causes : Activated carbon failure, membrane damage, water tank contamination.
Solution : Replace activated carbon, replace membrane, and clean and disinfect water storage tank.
III. Operational Faults
Causes : air intake, bearing wear, impeller blockage, motor failure.
Solution : Vent the air, replace the bearing/lubricate, clean the impeller, and repair the motor.
Causes : Aging of seals, loose bolts, and corrosion of pipelines.
Solution : Replace the sealing ring, tighten the bolts, and replace the corroded pipes.
IV. Maintenance Recommendations
Routine inspection : Monitor parameters such as pressure, flow rate, and conductivity every 2 hours, and handle any abnormalities promptly.
Regular maintenance : Clean the dosing system and perform backwash pretreatment weekly; flush the RO membrane and calibrate the instruments monthly; replace the filter cartridge and evaluate membrane performance quarterly.
Troubleshooting : Follow the order of "pre-processing first, then core unit, and finally auxiliary components" to avoid blind disassembly.
The above measures can effectively reduce the occurrence of malfunctions and ensure the long-term stable operation of equipment.